LEM HTB100-P
Current Transducers HTB 50~400-P and HTB 50~100-TP
FEATURES
● Hall effect measuring principle● Galvanic isolation between primary
● Isolation voltage 2500V
● Low power consumption
● Primary bus bar option for 50A and 100A version for ease of connection and secondary circuit VC IC Vd R IS VOUT ROUT RL Supply voltage (±5 %)2) Current consumption R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn Isolation resistance @ 500 VDC Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C Output internal resistance Load resistance +12 .. +15 V <15 mA 2.5 kV >500 MΩ VOE ±1.667 V 100 Ω ≥10 kΩ Accuracy - Dynamic performance data Special
FEATURES
● Single power supply from 12V to 15V ε X L VOE VOH VOT TC ε G tr f Accuracy @ IPN, TA = 25°C (without offset) <±1 % of IPN Linearity (0 .. ± IPN) <±1 % of IPN Electrical offset voltage, TA = 25°C Vc/2±30 mV Hysteresis offset voltage @ IP = 0; after an excursion of 3 x IPN <±0.5 % of IPN Thermal drift of VOE HTB 50-(T)P/SP5 <±1.0 mV/K HTB 100-(T)P..400-P/SP5 <±0.5 mV/K Thermal drift (% of reading) <±0.05 %/K Response time @ 90% of IP <3 µs Frequency bandwidth (-3 dB)3) DC ..