LB100-S Datasheet Text
Current Transducer LB 100-S/SP3
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
100 A
Electrical data
IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance with ± 15 V ISN KN VC IC Vd @ ± 100 A max @ ± 200 A max 100 0 .. ± 200 RM min RM max 0 0 100 1 : 1000 ± 15 20 + IS 5 1) 85 30 A A W W mA V mA kV
Features
- Closed loop (pensated) current transducer using the Hall effect
- Insulated plastic case recognized according to UL 94-V0.
Special Features
- VC = ± 15 (± 5 %) V
- Better zero crossing performance
- TA = + 10°C .. + 50°C
- Potted.
Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
Advantages
- Excellent accuracy
- Very good linearity
- Low temperature drift
- Optimized response time
- Wide frequency bandwidth
- No insertion losses
- High immunity to external interference
Accuracy
- Dynamic performance data e
X
L
Accuracy @ IPN, TA = 25°C Linearity Offset current @ IP = 0, TA = 25°C Thermal drift of IO + 10°C .. + 50°C Response time 2) @ 90 % of IPN di/dt accurately followed Frequency bandwidth (- 1 dB) Zero crossing distortion