LF2005-S - Current Transducer

Key Features

  • Closed loop (compensated) current transducer using the Hall effect.
  • Insulating plastic case recognized according to UL 94-V0. Special features.
  • IP M = 0 ±3700 A.
  • Ud = 12 kV.
  • TA =.
  • 40 °C (.
  • 50 °C) +85 °C.
  • Secondary connection on shielded cable 3 × 0.5 mm2.
  • Shield between primary and secondary connected to the cable screening.
  • Customer marking. Advantages.
  • Excellent accuracy.
  • Very good linearity.
  • Low temperature drift.
  • O.

📥 Download Datasheet

Datasheet Details

Part number LF2005-S
Manufacturer LEM
File Size 374.76 KB
Description Current Transducer
Datasheet download datasheet LF2005-S Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Current Transducer LF 2005-S/SP8 For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. IP N = 2000 A 16143 Electrical data IP N Primary nominal RMS current 2000 A IP M Primary current, measuring range @ ±24 V ÎP max Primary withstand peak current (maximum) 1) 0 ... ±3700 A 80 kA RM Measuring resistance @ TA = 70 °C TA = 85 °C with ±15 V with ±24 V @ ±1800 A max @ ±2100 A max @ ±2200 A max @ ±2000 A max @ ±3000 A max @ ±3500 A max @ ±3700 A max R R M min M max 0 24.4 @ ±1760 A 2) 0 5.5 @ ±2050 A 2) 0 4.2 3 27.2 3 10.2 @ ±2900 A 2) 3 5.3 @ ±3400 A 2) 3 3.