Datasheet4U Logo Datasheet4U.com

LTC600-S - Current Transducer

Key Features

  • Closed loop (compensated) current transducer using the Hall effect @ ± 500 A max @ ± 1200 A max @ ± 500 A max @ ± 1500 A max.
  • Insulated plastic case recognized according to UL 94-V0.
  • Railway equipment. Secondary nominal r. m. s. current Conversion ratio Supply voltage (± 5 %) Current consumption 100 mA 1 : 5000 ± 15 . . 24 V < 30 (@±24V)+ IS mA Advantages.
  • Excellent accuracy Very good linearity Lo.

📥 Download Datasheet

Datasheet Details

Part number LTC600-S
Manufacturer LEM
File Size 260.21 KB
Description Current Transducer
Datasheet download datasheet LTC600-S Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Current Transducer LTC 600-S For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 500 A Electrical data IPN IP ÎP RM Primary nominal r.m.s. current Primary current, measuring range @ 24 V Max overload not measurable Measuring resistance with ± 15 V with ± 24 V ISN KN VC IC www.DataSheet4U.com 500 A 0 .. ± 1500 A 10 / 10 kA/ms RM min RM max 0 0 0 0 70 5 150 20 Ω Ω Ω Ω Features • Closed loop (compensated) current transducer using the Hall effect @ ± 500 A max @ ± 1200 A max @ ± 500 A max @ ± 1500 A max • Insulated plastic case recognized according to UL 94-V0 • Railway equipment. Secondary nominal r.m.s.