Current Transducer LTS 6-NP
For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.
IP N = 6 At
Electrical data
IP N IP M IP Vout
G NS RL RI M TCRI M UC IC
Primary nominal RMS current Primary current, measuring range Overload capability Output voltage (analog) @ IP
@ IP = 0 Sensitivity Number of secondary turns (±0.1 %) Load resistance Internal measuring resistance (±0.5 %) Temperature coefficient of RI M Supply voltage (±5 %) Current consumption @ UC = 5 V Typical
Accuracy - Dynamic performance data
6
At
0 … ±19.2
At
250
At
2.5 ±(0.625 × IP/ IP N) V
2.5 1)
V
104.16
mV/A
2000
≥ 2
kΩ
208.