Voltage Transducer LV 25-1000
For the electronic measurement of voltages: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.
UP N = 1000 V
Electrical data
UP N Primary nominal RMS voltage
UP M Primary voltage, measuring range
IP N Primary nominal RMS current
RM
Measuring resistance
with ±12 V
@ ±1000 V max
@ ±1500 V max
with ±15 V
@ ±1000 V max
@ ±1500 V max
IS N Secondary nominal RMS current
NP/NS UC IC
Turns ratio Supply voltage (±5 %) Current consumption
Accuracy - Dynamic performance data
1000
V
0 ... ±1500
V
8
mA
R R M min
M max
30 200
Ω
30 100
Ω
100 320
Ω
100 180
Ω
25
mA
1000 V : 25 mA