Datasheet4U Logo Datasheet4U.com

LV25-1200 - Voltage Transducer

📥 Download Datasheet

Datasheet Details

Part number LV25-1200
Manufacturer LEM
File Size 356.14 KB
Description Voltage Transducer
Datasheet download datasheet LV25-1200 Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Voltage Transducer LV 25-1200 For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. VPN = 1200 V Electrical data VPN Primary nominal rms voltage VPM Primary voltage, measuring range IPN Primary nominal rms current RM Measuring resistance with ± 12 V @ ± 1200 V max @ ± 1800 V max with ± 15 V @ ± 1200 V max @ ± 1800 V max I SN Secondary nominal rms current KN Conversion ratio UC Supply voltage (± 5 %) IC Current consumption Accuracy - Dynamic performance data 1200 V 0 .. ± 1800 V 6.7 mA R R M min M max 30 200 Ω 30 100 Ω 100 320 Ω 100 180 Ω 25 mA 1200 V : 25 mA ± 12 ..