NNC-930A - Current Transducers NNC-920~960A

Key Features

  • 920A 930A 940A 950A 960A NNC NNC NNC NNC NNC -.
  • Hall effect measuring principle.
  • Galvanic isolation between primary.
  • Isolation voltage 3000 V~.
  • Low power consumption V mA kV 500 and secondary circuit VC IC Vd Vb V R IS VOUT ROUT RL Supply voltage (± 5 %) Current consumption R. m. s. voltage for AC isolation test, 50/60Hz, 1 mn R. m. s. rated voltage, safe separation Isolation resistance @ 500 VDC Output voltage @ ± IPN , RL = 10 kΩ , T A = 25°C Output interna.

📥 Download Datasheet

Datasheet Details

Part number NNC-930A
Manufacturer LEM
File Size 81.61 KB
Description Current Transducers NNC-920~960A
Datasheet download datasheet NNC-930A Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Current Transducers NNC-920 .. 960A For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 2000 .. 6000 A Electrical data Primary nominal r.m.s. current IPN (A) 2000 3000 4000 5000 6000 Primary current measuring range IP (A) ± ± ± ± ± 2200 3300 4400 5500 6600 Type Features 920A 930A 940A 950A 960A NNC NNC NNC NNC NNC - • Hall effect measuring principle • Galvanic isolation between primary • Isolation voltage 3000 V~ • Low power consumption V mA kV 500 and secondary circuit VC IC Vd Vb V R IS VOUT ROUT RL Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn R.m.s.