Legerity AM79M574

The metallic current (AC and DC) between A(TIP) and B(RING) = 1000 x the current into this pin. The networks that program receive gain, two-wire impedance, and feed resistance all c
Part No. AM79M574
Datasheet AM79M574 Download
Manufacturer
Legerity
Description Metering Subscriber Line Interface Circuit
Buy Stock & Price
AM79M574 datasheet page 1 preview

DESCRIPTION

Am79M574 Subscriber Line Interface Circuit Valid Combinations Valid Combinations Am79M574 –1 –2 JC Valid Combinations list configurations planned to be supported in volume for this device. Consult the local Legerity sales office to confirm availability of specific valid combinations, to check on newly released combinations, and to obtain additional data on Legerity’s standard military grade products. Note: * Functionality of the device from 0°C to +70°C is guaranteed by production testing. Performance from –40°C to +85°C is guaranteed by characterization and periodic sampling of production units. 2 Am79M574 Data Sheet CONNECTION DIAGRAM Top View RINGOUT B(RING) A(TIP) 31 BGND VREG VCC 32 30 4 3 2 1 DB TP TESTOUT L VBAT QBAT CHS CHCLK C4 E1 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 29 28 27 26 25 24 23 22 21 TP DA RD HPB HPA VTX VEE RSN AGND Notes: 1. Pin 1 is marked for orientation. 2. TP is a thermal conduction pin tied to substrate (QBAT). 3. NC = No connect SLIC Product...