Datasheet4U Logo Datasheet4U.com

LT1025 - Micropower Thermocouple Cold Junction Compensator

Key Features

  • s 80µA Supply Current s 4V to 36V Operation s 0.5°C Initial Accuracy (A Version) s Compatible with Standard Thermocouples (E, J, K, R, S, T) s Auxiliary 10mV/°C Output s Available in 8-Lead PDIP and SO Packages U.

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
LT1025 Micropower Thermocouple Cold Junction Compensator UW U FEATURES s 80µA Supply Current s 4V to 36V Operation s 0.5°C Initial Accuracy (A Version) s Compatible with Standard Thermocouples (E, J, K, R, S, T) s Auxiliary 10mV/°C Output s Available in 8-Lead PDIP and SO Packages U APPLICATIO S s Thermocouple Cold Junction Compensator s Centigrade Thermometer s Temperature Compensation Network DESCRIPTIO The LT®1025 is a micropower thermocouple cold junction compensator for use with type E, J, K, R, S, and T thermocouples. It utilizes wafer level and post-package trimming to achieve 0.5°C initial accuracy. Special curvature correction circuitry is used to match the “bow” found in all thermocouples so that accurate cold junction compensation is maintained over a wider temperature range.