Link-PP LP1234
10/100Base-TX Quad Port Transformer
ELECTRICAL SPECIFICATIONS
@25 --- Operating Temperature 0 to 70 Insertion Part Loss Number %dB MAX& 0.1-100MHz 2-30 MHz LP1140 -1.0 -18 LP1164 -1.0 -18 LP12341 -1.4 -18 LP12401 -1.0 -16.5 1.Operating Temperature -40' to +85' Return Loss %dB MIN& 40 MHz -14.4 -14.4 -14.4 -16 50 MHz -13.1 -13.1 -13.1 -15.5 60-80 MHz -12 -12 -12 -12 1 KHz -65 -55 -55 -60 Crosstalk %dB MIN& 30 MHz -50 -45 -45 -43 60 MHz -40 -40 -40 -38 100 MHz -35 -33 -33 -33 Differential to Common Mode Rejection%dB TYP& 1-60MHz 60-200MHz -40 -35 -37 -25 -37 -25 -43 -27 Hipot (Vrms ) 1500 1500 1500 1500 1500 LP11