LTC0060-52 Broadband Access Transformer Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and 250V working voltage RoHS Compliant Excellent THD performance Operating Temperature -40°C to 85°C OCL: D.C.R: Turn Ratio Hi-POT Electrical Specifications @25℃ PIN 1-2= 4.7mH ±30% @ 10KHz/0.1V/Ser. PIN 4-3= 4.7mH ±30% @ 10KHz/0.1V/Ser. PIN 1-2= 900 mohm Max. PIN 4-3= 900 mohm Max. PIN 1-2 to PIN4-3 = 1±2%:1 Pri.-Sec. = 750V Dimensions (Units: mm) Schematic Form Ver. A LTC0060 LinkCom DATE CODE -52 G Mark 1. DATE CODE----YYWW 2. G----RoHS Free Datasheet http://www.nDatasheet.