Littelfuse SAC30
The SAC Series is designed specifically to protect sensitive electronic equipment from voltage transients induced by lightning and other transient voltage events.SAC30 Specifications
- Mount Type : Through Hole
- Operating Voltage : 30V
- Polarity : Unidirectional
- Min Breakdown Voltage : 33.3V
- Terminals : 2
- Test Current : 1mA
- Channels : 1
- Max Power Dissipation : 3W
- Capacitance : 50pF
- Termination : Axial
- Max Operating Temp : 175°C
- Min Operating Temp : -65°C
Source:
Octopart
DESCRIPTION
FEATURES
Agency Approvals AGENCY AGENCY FILE NUMBER E230531MAXIMUM RATINGS
and Thermal Characteristics (TA=25OC unless otherwise noted) Parameter Symbol Peak Pulse Power Dissipation by 10/1000μs Test Waveform (Fig.1) (Note 1) PPPM Steady State Power Dissipation on Infinite Heat Sink at TL=75ºC ) Operating Junction and Storage Temperature Range PD TJ, TSTG Typical Thermal Resistance Junction to Lead RθJL Typical Thermal Resistance Junction to Ambient RθJA Value 500 3.0 -65 to 175 20 75 Unit W W °C °C/W °C/W Note: 1. Non-repetitive current pulse , per Fig. 3 and derated above TJ (initial) = 25OC per Fig. 2.● 500W peak pulse power capability at 10/1000μs waveform, repetition