Datasheet4U Logo Datasheet4U.com

TD302DCAN - Industrial Bus

Features

  • Integrated high efficiency isolated DC/DC converter.
  • Two-port isolation (2.5kVDC).
  • High baud rate up to 1Mbps.
  • Operating ambient temperature range: -40℃ to +105℃.
  • Complies with ISO 11898 standard.
  • An unpowered node does not disturb the bus lines.
  • The bus supports maximum 110 nodes.
  • Set isolation and ESD bus protection in one RoHS The TD302DCAN/ TD502DCAN series’ main function is to convert TTL / CMOS level into isolated CAN bus differential level signals.

📥 Download Datasheet

Datasheet preview – TD302DCAN

Datasheet Details

Part number TD302DCAN
Manufacturer MORNSUN
File Size 1.32 MB
Description Industrial Bus
Datasheet download datasheet TD302DCAN Datasheet
Additional preview pages of the TD302DCAN datasheet.
Other Datasheets by MORNSUN

Full PDF Text Transcription

Click to expand full text
Industrial Bus TDx02DCAN Series Duplex universal CAN isolation transceiver module FEATURES  Integrated high efficiency isolated DC/DC converter  Two-port isolation (2.5kVDC)  High baud rate up to 1Mbps  Operating ambient temperature range: -40℃ to +105℃  Complies with ISO 11898 standard  An unpowered node does not disturb the bus lines  The bus supports maximum 110 nodes  Set isolation and ESD bus protection in one RoHS The TD302DCAN/ TD502DCAN series’ main function is to convert TTL / CMOS level into isolated CAN bus differential level signals. The use of IC integrated technology allows for power isolation, signal isolation, CAN transceiver and bus protection all in one single CAN bus transceiver module, which withstands an isolation test voltage of 2500VDC.