DS1870 Description

It uses lookup tables (LUTs) to control 256-position potentiometers based on the amplifier’s temperature and drain voltage or current (or other external monitored signal). With its internal temperature sensor and multichannel A/D converter (ADC), the DS1870 provides a cost-effective solution that improves the amplifier’s efficiency by using nonlinear pensation schemes that are not possible with conventional biasing...

DS1870 Key Features

  • Two-Channel Solution for Programmable RF Bias Control
  • The Potentiometer’s Position is Automatically Updated to pensate for the Ambient Temperature and the Drain Voltage or Cu
  • A Five-Channel, 13-Bit ADC Continuously Monitors the Ambient Temperature, VCC, VD, ID1, and ID2
  • Hi/Lo Alarms for Each ADC Channel can Trigger a Fault Output
  • Nonvolatile Memory for the Device Settings, Lookup Tables, and 32-Bytes of User Memory
  • I2C™-patible Serial Interface with Up to Eight Devices on the Same Serial Bus
  • Single 5V Power Supply
  • Small 16-Pin TSSOP Package
  • 40°C to +95°C Operational Temperature Range