Datasheet4U Logo Datasheet4U.com

MAX16030 - Sequencing/Supervisory Circuits

Download the MAX16030 datasheet PDF. This datasheet also covers the MAX16025 variant, as both devices belong to the same sequencing/supervisory circuits family and are provided as variant models within a single manufacturer datasheet.

General Description

The MAX16025

MAX16030 are dual-/triple-/quad-voltage monitors and sequencers that are offered in a small TQFN package.

Key Features

  • o 2.2V to 28V Operating Voltage Range o Fixed Thresholds for 3.3V, 2.5V, 1.8V, 1.5V, and 1.2V Systems o 1.5% Accurate Adjustable Threshold Monitors Voltages Down to 0.5V o 2.7% Accurate Fixed Thresholds Over Temperature o Fixed (140ms min)/Capacitor-Adjustable Delay Timing o Independent Open-Drain/Push-Pull Outputs o Enable Inputs for Each Monitored Voltage o 9 Logic-Selectable Threshold Options o Manual Reset and Tolerance Select (5%/10%) Inputs o Small, 4mm x 4mm TQFN Package o Fully Specified.

📥 Download Datasheet

Note: The manufacturer provides a single datasheet file (MAX16025_MaximIntegratedProducts.pdf) that lists specifications for multiple related part numbers.

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
19-0525; Rev 1; 6/06 Dual-/Triple-/Quad-Voltage, CapacitorAdjustable, Sequencing/Supervisory Circuits General Description The MAX16025–MAX16030 are dual-/triple-/quad-voltage monitors and sequencers that are offered in a small TQFN package. These devices offer enormous design flexibility as they allow fixed and adjustable thresholds to be selected through logic inputs and provide sequence timing through small external capacitors. These versatile devices are ideal for use in a wide variety of multivoltage applications. www.DataSheet4U.com As the voltage at each monitored input exceeds its Features o 2.2V to 28V Operating Voltage Range o Fixed Thresholds for 3.3V, 2.5V, 1.8V, 1.5V, and 1.2V Systems o 1.5% Accurate Adjustable Threshold Monitors Voltages Down to 0.5V o 2.