MAX31850 Description

The MAX31850/MAX31851 cold-junction pensated, 1-WireM thermocouple-to-digital converters perform cold-junction pensation and digitize the signal from a K-, J-, N-, T-, S-, R-, or E-type thermocouple. The converters resolve temperatures to 0.25NC, allow readings as high as +1768NC and as low as -270NC, and exhibit thermocouple accuracy of 8 LSBs (2NC) for temperatures ranging from -200NC to +700NC. munication with...

MAX31850 Key Features

  • 14-Bit, 0.25NC Resolution
  • Integrated Cold-Junction pensation
  • Available for Multiple Thermocouples Types: Supports K-, J-, N-, T-, and E-Type (MAX31850); S- and R-Type (MAX31851)
  • Detects Thermocouple Shorts to GND or VDD
  • Detects Open Thermocouple
  • 1-Wire Interface (Read-Only); Power Can Be Obtained from Interface (Parasite-Powered Mode)