The MAX6505
MAX6508 temperature switches have dual logic outputs that assert when the die temperature crosses their trip thresholds.
Trip thresholds are factory programmed to convenient temperatures in 5°C increments.
Features
- ±0.5°C (typ) Threshold Accuracy Over Full Temperature Range.
- No External Components Required.
- Low Cost.
- 30µA (typ) Supply Current.
- Factory-Programmed Thresholds from -40°C to
+125°C in 5°C Increments.
- Open-Drain Outputs (MAX6505/MAX6507),
Push-Pull Outputs (MAX6506/MAX6508).
- Pin Selectable 2°C, 10°C Hysteresis
(MAX6507/MAX6508).
- Pin Selectable +5°C, +10°C, +20°C, +30°C
TALARM - TWARN (MAX6505/MAX6506).
- SOT23 Packag.