MAX6508 Overview
The MAX6505 MAX6508 temperature switches have dual logic outputs that assert when the die temperature crosses their trip thresholds. Trip thresholds are factory programmed to convenient temperatures in 5°C increments. The MAX6505/MAX6506 have an ALARM output that asserts when the temperature is above the factory-programmed thresholds (available from -40°C to +125°C).
MAX6508 Key Features
- ±0.5°C (typ) Threshold Accuracy Over Full Temperature Range
- No External ponents Required
- Low Cost
- 30µA (typ) Supply Current
- Open-Drain Outputs (MAX6505/MAX6507)
- Pin Selectable 2°C, 10°C Hysteresis
- Pin Selectable +5°C, +10°C, +20°C, +30°C
- TWARN (MAX6505/MAX6506)
- SOT23 Package