Datasheet4U Logo Datasheet4U.com

MAX6648 - Precision SMBus-Compatible Remote/Local Temperature Sensors

General Description

The MAX6648/MAX6692 are precise, two-channel digital temperature sensors.

They accurately measure the temperature of their own die and a remote PN junction, and report the temperature in digital form using a 2-wire serial interface.

Key Features

  • o Dual Channel: Measures Remote and Local Temperature o 0.125°C Resolution o High Accuracy: ±0.8°C (max) from +25°C to +125°C (Remote), and ±2°C (max) from +60°C to +100°C (Local) o Two Alarm Outputs: ALERT and OVERT o Two Default OVERT Thresholds Available MAX6648: +110°C MAX6692: +85°C o Programmable Conversion Rate o SMBus-Compatible Interface o SMBus Timeout o Programmable Under/Overtemperature Alarm Thresholds MAX6648/MAX6692 Ordering Information PART TEMP RANGE.

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
19-2545; Rev 1; 10/02 Precision SMBus-Compatible Remote/Local Temperature Sensors with Overtemperature Alarms General Description The MAX6648/MAX6692 are precise, two-channel digital temperature sensors. They accurately measure the temperature of their own die and a remote PN junction, and report the temperature in digital form using a 2-wire serial interface. The remote PN junction is typically the emitter-base junction of a common-collector PNP on a CPU, FPGA, or ASIC. The 2-wire serial interface accepts standard System Management Bus (SMBus)™ write byte, read byte, send byte, and receive byte commands to read the temperature data and to program the alarm thresholds. To enhance system reliability, the MAX6648/MAX6692 include an SMBus timeout.