19-0005; Rev 2; 6/97
10µA, Low-Dropout, Precision Voltage References
General Description
The MAX872/MAX874 precision 2.5V and 4.096V micropower voltage references consume a maximum of only 10µA and operate from supply voltages up to 20V. The combination of ultra-low quiescent current and low 200mV dropout makes them ideal for battery-powered equipment. They source and sink up to 500µA with only 200mV input voltage headroom, which makes the 2.5V MAX872 ideal for use with a 3V supply and the 4.096V MAX874 ideal for use with a 5V supply. Initial accuracy of 0.2% at +25 °C (±5mV for the MAX872, ±8mV for the MAX874) and low 40ppm/°C max drift make these references suitable for a wide range of precision applications. o Output Voltage 2.500V ±0.2% (MAX872) 4.096V ±0.