MCP3910 - 3V Two-Channel Analog Front End

Key Features

  • Two Synchronous Sampling 24-bit Resolution Delta-Sigma A/D Converters.
  • 93.5 dB SINAD, -107 dBc Total Harmonic Distortion (THD) (up to 35th harmonic), 112 dB Spurious-Free Dynamic Range (SFDR) for Each Channel.
  • Flexible Serial Interface that Includes Both SPI and a Simple 2-Wire Interface Ideal for Polyphase Shunt Energy Meters.
  • Enables 0.1% Typical Active Power Measurement Error over a 10,000:1 Dynamic Range.
  • Advanced Security Features: - 16-bit Cyc.

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
MCP3910 3V Two-Channel Analog Front End Features: • Two Synchronous Sampling 24-bit Resolution Delta-Sigma A/D Converters • 93.5 dB SINAD, -107 dBc Total Harmonic Distortion (THD) (up to 35th harmonic), 112 dB Spurious-Free Dynamic Range (SFDR) for Each Channel • Flexible Serial Interface that Includes Both SPI and a Simple 2-Wire Interface Ideal for Polyphase Shunt Energy Meters • Enables 0.1% Typical Active Power Measurement Error over a 10,000:1 Dynamic Range • Advanced Security Features: - 16-bit Cyclic Redundancy Check (CRC) Checksum on All Communications for Secure Data Transfers - 16-bit Cyclic Redundancy Check (CRC) Checksum and Interrupt Alert for RegisterMap Configuration - Register-Map Lock with 8-bit Secure Key • 2.7V – 3.