Datasheet Summary
PAC194X
Single/Multi-Channel Power Monitor with Accumulator, 9V Full-Scale Range
Features
- High-Side/Low-Side Current Monitor with One, Two, Three or Four Channels:
- 100 mV Full-Scale Range (FSR) for current sense voltage
- 16-bit resolution for current measurement
- Programmable FSR: -50 mv to +50 mv
- External sense resistor sets the full-scale current range
- Very low input current simplifies routing
- Voltage Monitor with Wide VBUS Range
- 0V to 9V FSR
- 4.5V programmable VBUS option
- 16-bit resolution for voltage measurements
- VSOURCE Can Be Applied before VDD Is Applied
- Real-Time Auto-Calibration of Offset Error for
Voltage and Current
- 1% Power Measurement Accuracy over a...