Click to expand full text
Ultra-Reliable
Low Pass Filters
DC to 5400 MHz
Maximum Ratings
Operating Temperature Storage Temperature -55°C to 100°C -55°C to 100°C
! NEW
VLP-SERIES
Features
• • • • rugged unibody construction low insertion loss for passband, 0.7 dB typ. high power handling, up to 15W low cost
CASE STYLE: FF704 PRICE: $24.95 ea. QTY (1-9)
Outline Drawing Electrical Specifications (TAMB=25°C)
MODEL NO. PASSBAND (MHz)
(loss < 1dB) Typ. VLP-11 VLP-16 VLP-20 VLP-24 VLP-41 VLP-54 VLP-64 * Derate linearly to
fco, MHz Nom.
(loss 3 dB) Typ.
STOP BAND (MHz)
(loss >20 dB) 1500 2100 2700 3400 5500 7100 9000 (loss >40 dB) 2000-3500 2700-4000 3300-3880 4400 — — — fr20 dB Typ. 5500 7000 7200 8000 11000 9500 18000
VSWR (:1)
Passband Typ. 1.2 1.1 1.1 1.2 1.2 1.2 1.1
POWER INPUT* (W)
Pmax.