NEA016
NEA016 is Non-Isolated 16A SIP/SMT DC/DC Converters manufactured by Murata.
Volant NEA016 Series
Non-Isolated 16A SIP/SMT DC/DC Converters
..
Features
: 9 Small size, minimal footprint
- SMT/SIP package 9 16A Output Current (all voltages) 9 High Efficiency: up to 94% 9 High reliability 9 Ro HS pliant 9 Cost efficient open frame design 9 Output voltage programmable by an external resistor. 9 Monotonic Start with Pre-Bias. 9 +ve Enable Logic and
- ve Enable Logic models available
Output Vout (V) 0.75 1.2 1.5 1.8 2.0 2.5 3.3 5.0 Iout (A) 16 16 16 16 16 16 16 16 PARD (m Vp-p) Typ. 50 50 50 50 50 50 50 50 Max. 75 75 75 75 75 75 75 75 Regulation Max Line +/-0.2% +/-0.2% +/-0.2% +/-0.2% +/-0.2% +/-0.2% +/-0.2% +/-0.2% Load +/-0.5% +/-0.5% +/-0.5% +/-0.5% +/-0.5% +/-0.5% +/-0.5% +/-0.5%
Input Vin Nom. (V) 12 12 12 12 12 12 12 12
Efficiency Range (V) Iin Typ (A) 1.299 1.928 2.326 2.727 2.996 3.704 4.783 7.092 Full Load Typ. 77% 83% 86% 88% 89% 90% 92% 94%
- 14 8.3
- 14 8.3
- 14 8.3
- 14 8.3
- 14 8.3
- 14 8.3
- 14 8.3
- 14
Technical enquiries email: sales@murata-ps. , tel: +508 339 3000
NEA016_6200860000_B01_21/04/08
.. Volant NEA016 Series Murata Power Solutions Non-Isolated 16A SIP/SMT DC/DC Converters
Input Characteristics Input Voltage Operating Range Input Reflected Ripple Current Inrush Current Transient Input Filter Type (external) Input Turn ON Threshold Input Turn OFF Threshold ON Control OFF Control Output Characteristics Vout Accuracy Output Loading Output Ripple & Noise @ 20Mhz Bandwidth. Maximum Capacitive Load Vout Trim Range (Nom) Total Accuracy Current Limit Output Line Regulation Output Load Regulation Turn-on Overshoot SC Protection Technique Pre-bias Start-up at output
Notes & Conditions
Min 8.3
Typ. 12 200 100 8.5 8.0
Max 14 0.2
Units Vdc m A p-p A2s μF V V
Open Circuit or =Vin < 0.4Vdc Notes & Conditions 100% load Min -1.5 0 Typ. Max +1.5 16 75 8000 5.0 <2% 23 -0.2 -0.5 Hiccup with auto recovery Unit starts monotonically with prebias Notes & Conditions 50% step, 0.1A/μs...