DM54LS73A
DM54LS73A is Dual Negative-Edge-Triggered Master-Slave J-K Flip-Flops manufactured by National Semiconductor.
Description
This device contains two independent negative-edge-triggered J-K flip-flops with plementary outputs The J and K data is processed by the flip-flops on the falling edge of the clock pulse The clock triggering occurs at a voltage level and is not directly related to the transition time of the negative going edge of the clock pulse The data on the J and K inputs is allowed to change while the clock is high or low without affecting the outputs as long as setup and hold times are not violated A low logic level on the clear input will reset the outputs regardless of the levels of the other inputs
Connection Diagram
Dual-In-Line Package
..
TL F 6372
- 1
Order Number DM54LS73AJ DM54LS73AW DM74LS73AM or DM74LS73AN See NS Package Number J14A M14A N14A or W14B
Function Table
Inputs CLR L H H H H H CLK X J X L H L H X K X L L H H X Q L Q0 H L Toggle Q0 Q0 Outputs Q H Q0 L H v v v v
H e High Logic Level L e Low Logic Level X e Either Low or High Logic Level v e Negative going edge of pulse
Q0 e The output logic level before the indicated input conditions were established Toggle e Each output changes to the plement of its previous level on each falling edge of the clock pulse
C1995 National Semiconductor Corporation
TL F 6372
RRD-B30M105 Printed in U S A
Absolute Maximum Ratings (Note)
If Military Aerospace specified devices are required please contact the National Semiconductor Sales Office Distributors for availability and specifications Supply Voltage 7V Input Voltage 7V Operating Free Air Temperature Range b 55 C to a 125 C DM54LS DM74LS 0 C to a 70 C b 65 C to a 150 C Storage Temperature Range Note The ‘‘Absolute Maximum Ratings’’ are those values beyond which the safety of the device cannot be guaranteed The device should not be operated at these limits The parametric values defined in the ‘‘Electrical Characteristics’’ table are not guaranteed at the absolute maximum ratings The ‘‘Remended Operating Conditions’’ table will define the conditions...