Click to expand full text
10A Avg. 300 Volts FRED
TCU10A30-11A
INSTANTANEOUS FORWARD CURRENT (A)
50
20 10
5
2 1 0.5
0
FORWARD CURRENT VS. VOLTAGE TCU10A30-11A (per Arm)
0˚ 180˚ θ
CONDUCTION ANGLE
16
AVERAGE FORWARD POWER DISSIPATION (W)
14
12
10
8
6
Tj=25˚C Tj=150˚C
4 2
0.4 0.8 1.2 1.6 2.0 INSTANTANEOUS FORWARD VOLTAGE (V)
2.4
0 0
AVERAGE FORWARD POWER DISSIPATION TCU10A30-11A
RECT 180˚ SINE WAVE
0˚ 180˚ θ
CONDUCTION ANGLE
AVERAGE FORWARD CURRENT VS. CASE TEMPERATURE
6 RECT 180˚
TCU10A30-11A
5 SINE WAVE
AVERAGE FORWARD CURRENT (A)
4
3
2
1
12345 AVERAGE FORWARD CURRENT (A)
6
0 0 25 50 75 100 125 150 CASE TEMPERATURE (˚C)
120 100
80 60 40 20
0 0.02
SURGE CURRENT RATINGS f=50Hz,Harf Sine Wave,Non-Repetitive,No Load
TCU10A30-11A
0.02s
I FSM
0.05 0.1
0.2
0.