RP170N
FEATURES
- Input Voltage Range (Maximum Rating) 2.6 V to 10.0 V (12 V)
- Operating Temperature - 40°C to 105°C (RP170xx1x-xx-AE)
- 40°C to 125°C (RP170xx1x-xx-KE)
- Supply Current Typ. 23 A
- Standby Current Typ. 0.1 A
- Dropout Voltage Typ. 0.20 V (IOUT = 100 m A, VOUT = 3.0 V) Typ. 0.77 V (IOUT = 300 m A, VOUT = 2.8 V)
- Ripple Rejection Typ. 70 d B (f = 1 k Hz)
- Temperature-Drift Coefficient of Output Voltage ...Typ. ±80 ppm/C
- Line Regulation Typ. 0.02%/V
- Output Voltage Accuracy ±1.0%
- Packages...