NSPU3061
Features
- Low Clamping Voltage
- Low Leakage
- Small Body Outline: 1.0 mm x 0.6 mm
- Protection for the Following IEC Standards:
IEC61000- 4- 2 Level 4: ±30 k V Contact Discharge IEC61000- 4- 5 (Lightning): 36 A (8/20 ms)
- These Devices are Pb- Free, Halogen Free/BFR Free and are Ro HS pliant
Typical Applications
- USB VBUS and CC Line Protection
- Microphone Line Protection
- GPIO Protection
Table 1. MAXIMUM RATINGS
Rating
Symbol
Value
Unit
IEC 61000- 4- 2 (ESD)
Contact
±30 k V
Air
±30
Operating Junction Temperature Range
- 65 to + °C
Storage Temperature Range
TSTG
- 65 to + °C 150
Minimum Peak Pulse Current
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality should not be assumed, damage may occur and reliability may be affected.
.onsemi.
MARKING DIAGRAM
X2DFN2 CASE 714AB
6M
6 = Specific Device Code M = Date Code
1 CATHODE
2 ANODE
ORDERING INFORMATION
Device...