• Part: EP151XXX
  • Description: Current Sense Transformers
  • Manufacturer: PCA ELECTRONICS
  • Size: 134.42 KB
Download EP151XXX Datasheet PDF

Datasheet Summary

.. Current Sense Transformers ELECTRONICS INC. EP151XXX & EP151XXX-LF - Frequency Range : 20 KHz to 50 KHz - Test Conditions : Termination : 50 Ω, 100 Ω & 200 Ω for 1 Volt/Ampere Scaling Peak Current Sense : 20 Amperes with 40% Duty Factor - Add “-LF” after part number for Lead-Free Electrical Parameters @ 25° C Part Number EP151686(-LF) EP151687A(-LF) EP151688(-LF) EP151717(-LF) EP151718(-LF) EP151719(-LF) Inductance (mH Min.) @ Pins 1 & 3 5 20 80 5 20 80 Turns (± 5%) 50 100 200 50 CT 100 CT 200 CT DCR (Ω Max.) @ Pins 1 & 3 0.6 1.2 4.0 0.6 1.2 4.0 Schematic A A A B B B Package A .375Max. (9.52) .670Max. (17.02) 1 Schematic B 1 2 3 3 .170 (4.32) PCA EP151XXX(-LF)...