PDI D8740200GT
The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency.FEATURES
●●
●
●
●
● Excellent linearity Superior return loss performance Extremely low distortion Optimal reliability Low noise Unconditionally stable under all terminations D8740200GT APPLICATION
● 40 to 870 MHz CATV amplifier systems
DESCRIPTION
● Hybrid Power Doubler amplifier module employing GaAs die GaAs Power Doubler Hybrid 40 – 870MHz 20.5dB min. Gain @ 870MHz 375mA max. @ 24VDC LIMITING VALUES In accordance with the Absolute Maximum Rating System (IEC 60134) SYMBOL Vi Vov Tstg Tmb PARAMETER RF input voltage (single tone) DC supply over-voltage (5 minutes) storage temperature operating mounting base temperature MIN. - 40 - 30 MAX. 75 30 + 100 + 100 UNIT dBmV V °C °C CHARACTERISTICS Table 1: S-Parameter, Noise Figure, DC Current; VB = 24V; Tmb = 30°C; ZS = ZL = 75 Ω SYMBOL Gp SL FL S11 S22 F Itot PARAMETER power gain slope flatness of frequency response input return loss 1) CONDITIONS f = 50 MHz f = 870 MHz f = 40 to 870 MHz f = 40 to 870 MHz (Peak to Valley) MIN. 19.5 20.5 0.6 20.0 19.0 17.0 20.0 19.0 18.0 - TYP.