Panasonic LKS1aF-18V
power relays
FEATURES
1. High sensitivity: 250mW The power-saving relay is highly sensitive at the nominal operating power of 250 mW (530 mW power consumption on LK relays). 2. High insulation resistance between contact and coil 1) Creepage distance and clearances between contact and coil: Min. 6 mm .236 inch (In compliance with IEC65) 2) Surge withstand voltage between contact and coil: 10,000 V or more 3. High noise immunity realized by the card separation structure between contact and coil 4. Popular terminal pitch in AV equipment field 5. Space-saving slim type Base area: Width 11 Length 24 mm Width .433 Length .945 inch 6. Conforms to the various safety standards UL/CSA, VDE, TÜV and SEMKO SEV approved SPECIFICATIONS Contact Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Rating (resistive load) Max. switching power Max.