PE125BUV
PE125BUV is CERMAX XENON ARC LAMPS manufactured by PerkinElmer Optoelectronics.
Description
The Cermax® xenon arc lamp is an innovative lamp design in the specialty lighting industry. These lamps were introduced in the early 1980’s and are now used in endoscopes in most major hospitals worldwide, in high brightness projection display systems, and for a wide variety of other high performance applications. The PE125BF and PE125BUV Cermax® lamps have an integrated parabolic reflector, enabling high intensity, focused output of ultraviolet, visible, and infrared radiation. With their internal reflector and rugged ceramic body construction, Cermax® lamps are the safest and most pact alternative to conventional quartz xenon lamps. This makes them ideal for applications that require a high degree of illumination control. Current-regulated or power-regulated power supplies with output ripples of less than 5% are remended. Single shot ignition pulses are advised because radio frequency starters may damage the lamps internal reflector. In addition to lamps, Perkin Elmer Optoelectronics manufactures Cermax® arc lamp power supplies, lamp holders, OEM lighting systems, and fiber optic light sources.
Applications
- Medical and industrial fiber optic illu-
- -
- -
- - minators Machine vision Infrared and visible spotlights/beacons Spectroscopy Microscopy UV Curing Video projection
. .perkinelmer./opto
PE125BF and PE125BUV
Operational Specifications
Description
Power Current Operating Voltage Ignition Voltage Temperature Lifetime- Nominal 125 watts 12 amps (DC) 11 volts (DC) 150ºÞ C (maximum) 1000 hours (500 hour warranty) Range 75-150 watts 7-14 amps (DC) 9.5-12.5 volts (DC)
Physical Specifications
Description
Arc Gap Reflector Geometry Weight Window Diameter
Specification
.044 inch (1.14mm) Parabolic Y2 = 0.5 X (inch) 130.8 grams 1 inch (25.4 mm)
17 kilovolts (remended minimum)
Focused Output at F/1.0 Lens
Description
6mm aperture 8mm aperture Visible Output 1050 Lumens 620 Lumens Total Output- 9.5 watts 5.6 watts
- End of lamp life is defined as...