Philips OSM9410
The OSM941Oseries is intended for application in single phase or three phase bridges or in voltage doubler circuits. The OSS9410series is intended for all kinds of high voltage rectification. The OSB9410series and OSM9410series are supplied with a centre tap (8 -32UNC).MECHANICAL DATA
see page 4 II 1 05B941USERIE51 OSM9410sERIES OSS 9410SERIES II All information applies to frequencies up to 400 Hz RATINGS Limiting values in accordance with the Absolute Maximum System (IEC 134) Voltages OSB9410 -41 -30 OSM9410 -4 -30 Crest working reverse voltage VRWM max. 2 15 kV OSS9410 -4 Crest working reverse voltage VRWM max. 4 29 -30 -1 29 30 kV Currents Average forward current (averaged over any 20 ms period) in free air up to Tamb = 35 °c in oil up to Toil = 35 °c Ip(AV) max. Ip(AV) max. 10 A 30 A Repetitive peak forward current IpRM max. 450 A Non -repetitive peak forward current t = 10 ms; half sine wave; T j = 175 °C prior to surge IpSM max. 800 A Reverse power dissipation OSB9410 -4 -6 -28 -30 Repetitive peak reverse power dis sipation...