Datasheet4U Logo Datasheet4U.com

PCT91CL - PCB Relay

Download the PCT91CL datasheet PDF. This datasheet also covers the PCT91EL variant, as both devices belong to the same pcb relay family and are provided as variant models within a single manufacturer datasheet.

Features

  • Energy Saving Latching Operation.
  • Most Popular Power PCB Relay.
  • 30, 40 or 50 Amp Switching Capacity.
  • Single Coil Latching.
  • UL Class F Insulation Standard.
  • Epoxy Sealed, Immersion Cleanable.
  • Lead Free and RoHS Compliant E93379 1 Form A (SPST-NO) 50 A 5,000 W 16 A 5 HP 1 Form B (SPST-NC) 50 A 5,000 W 16 A 5 HP 1 Form C (SPDT) NO NC 40 A 40 A PCT91DL 40 Amp Version Load Type Resistive 6,000 Cycles Incandescent Lamp 3,000 Cycles Electronic Ballast 6,000 Cycles.

📥 Download Datasheet

Note: The manufacturer provides a single datasheet file (PCT91EL-Picker.pdf) that lists specifications for multiple related part numbers.

Datasheet Details

Part number PCT91CL
Manufacturer Picker
File Size 533.44 KB
Description PCB Relay
Datasheet download datasheet PCT91CL Datasheet

Full PDF Text Transcription

Click to expand full text
30, 40 or 50 Amp Latching PCB Relay with Spade Contacts PCT91xL UL/CSA Ratings at 25C PCT91EL 50 Amp Version Load Type Resistive 6,000 Cycles Incandescent Lamp 3,000 Cycles Electronic Ballast 6,000 Cycles Motor Load 3,000 Cycles Voltage 277 VAC 240 VAC 280 VAC 277 VAC FEATURES  Energy Saving Latching Operation  Most Popular Power PCB Relay  30, 40 or 50 Amp Switching Capacity  Single Coil Latching  UL Class F Insulation Standard  Epoxy Sealed, Immersion Cleanable  Lead Free and RoHS Compliant E93379 1 Form A (SPST-NO) 50 A 5,000 W 16 A 5 HP 1 Form B (SPST-NC) 50 A 5,000 W 16 A 5 HP 1 Form C (SPDT) NO NC 40 A 40 A PCT91DL 40 Amp Version Load Type Resistive 6,000 Cycles Incandescent Lamp 3,000 Cycles Electronic Ballast 6,000 Cycles Motor Load 3,000 Cycles Voltage 277 VAC, 28V