GENERAL DESCRIPTION
Under the light load or no load conditions the PT2201 automatically decreases PWM frequency and enters burst mode operation thus the power loss on power MOSFET is reduced. Synchronized slope compensation has been implemented in the PT2201 to avoid potential sub harmonic oscillation caused by peak current control mode when operating under Continuous Conduct Mode. Moreover, the internal LEB on the current sense input removes the signal glitch due to snubber circuit diode reverse recovery and greatly reduces the external component count and system cost in the design. The PT2201 also features multi-level protections to enhance SMPS reliability including cycle by cycle Over Current Protection, Over Load Protection, programmable Over Û w Vm `R●yÑb € FEATURES