APPLICATIONS
Information section. 2. Initially the TISP must be in thermal equilibrium with 0°C < TJ <70°C. The surge may be repeated after the TISP returns to its initial conditions. 3. Above 70°C, derate linearly to zero at 150°C lead temperature. electrical characteristics for the T and R terminals, TJ = 25°C TISP4072F3 PARAMETER Repetitive peak offstate current Breakover voltage age Breakover current On-state voltage Holding current Critical rate of rise of off-state voltage Off-state current Off-state capacitance TEST CONDITIONS MIN TYP MAX ±10 ±72 ±86 ±0.15 ±0.15 ±5 ±10 Vd = 100 mV VD = 0, VD = -5 V VD = -50 V 82 49 25 140 85 40 82 49 25 ±0.6 ±3 ±0.15 ±5 ±10 140 85 40 ±0.15 ±96 ±0.6 ±3 MIN TISP4082F3 TYP MAX ±10 ±82 UNIT IDRM V(BO) V(BO) I(BO) VT IH dv/dt ID Coff NOTE VD = ±VDRM , 0°C < TJ < 70°C dv/dt = ±250 V/ms, RSOURCE = 300 Ω RSOURCE = 50 Ω, di/dt < 20 A/µs dv/dt = ±250 V/ms, RSOURCE = 300 Ω IT =