Click to expand full text
LOS, LOR, LOK 4000 15, 30 and 50 Watt AC-DC Converters
Universal input range 85...264 V AC Single output 5.1, 12, 24 or 48 V DC 3 kV AC I/O electric strength test voltage
LGA
• Compact design • Battery charger versions • Operating ambient temperature range –10...50 °C with convection cooling
Selection chart
Output Input voltage Rated power Uo nom Io nom Ui TA = 50°C [V DC] [A] [V AC] Po tot [W] 5.1 5.2 85...264 26 12 1.25 85...264 15 12 2.5 85...264 30 12 4 85...264 48 12...12.81...15 3.6 85...264 49 24 0.65 85...264 15 24 1.25 85...264 30 24 2 85...264 48 24...25.71...30 1.8 85...264 49 48 1 85...264 48 48...51.41...60 0.9 85...264 49 1 Setting voltage U o set for battery charger with R-input open circuit. 2 For minimum order quantity and lead time contact Power-One.