LS1301-7R
LS1301-7R is 100 Watt AC-DC Converters manufactured by Power-One.
- Part of the LS1301-7R_Power comparator family.
- Part of the LS1301-7R_Power comparator family.
S Series
100 Watt AC-DC Converters
Input voltage range from 85…264 V AC 1 or 2 isolated outputs up to 48 V DC 4 k V AC I/O electric strength test voltage
- Rugged electrical and mechanical design
- Wide input frequency range from 47...440 Hz
- Operating ambient temperature range
- 40...71 °C with convection cooling
Selection chart
Output 1 Output 2 Input voltage Type Options
Uo nom
[V DC] 5.1 12 15 24 24 30 48 12 15 24
Io nom
[A] 16 8 6.5 4.2 4 3.2 2 4 3.2 2
Uo nom
[V DC] 12 15 24
Io nom
[A] 4 3.2 2
Ui
[V AC] 85...264 85...264 85...264 85...264 85...264 85...264 85...264 85...264 85...264 85...264 LS 1001-7R LS 1301-7R LS 1501-7R LS 1601-7R LS 2320-7R LS 2540-7R LS 2660-7R LS 2320-7R LS 2540-7R LS 2660-7R -9, E, D, V, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1
.power-one.
Edition 4/04.2001
Cassette Style
Input
Input voltage AC Input frequency Input voltage DC Inrush current limitation wide input range
S Series
85...264 V AC 47...440 Hz 88...372 V DC by thermistor
Output
Efficiency Output voltage setting accuracy Output voltage switching noise Line regulation Load regulation Minimum load Current limitation Operation in parallel Hold-up time
Ui nom, Io nom Ui nom, Io nom up to 85% ±0.6% Uo nom IEC/EN 61204, total typ. 90 m Vpp Ui min...Ui max, Io nom typ. ±0.3% Uo nom Ui nom, 10...100% Io nom, symmetrical output load typ. 0.5% Uo nom not required 0A rectangular U/I characteristic typ. 110% Io nom by current limitation Ui nom, Io nom 80 ms
Control and...