Click to expand full text
www.DataSheet.co.kr
ECO-PACTM 3
Three Phase AC Controller Modules
Preliminary Data Sheet VRSM VDSM (V) 900 1300 1500 1700 VRRM VDRM (V) 800 1200 1400 1600 Type
PSUT 45 PSUH 45
W3C
IRMS = 3 x 44 A
VRRM= 800-1600 V
PSUT 45/08 PSUH 45/08 PSUT 45/12 PSUH 45/12 PSUT 45/14 PSUH 45/14 PSUT 45/16 PSUH 45/16
W3H
ECO-PACTM 3
Symbol
I RMS ITRMS ITAVM ITSM
Test Conditions
TVJ = TVJM TC = 85 °C; TVJ = 45 °C VR = 0 VR = 0 TVJ = 45 °C VR = 0 VR = 0
Maximum Ratings
44 32 20 320 350 290 320 510 500 420 420 150 A A A A A A A A²s A²s A²s A²s A/µs
Features
TC = 85 °C, 50-400 Hz (per phase) 180° sine, per thyristor t = 10 ms (50 Hz), sine t = 8.3 ms (60 Hz), sine (50 Hz), sine t = 8.3 ms (60 Hz), sine t = 10 ms (50 Hz), sine t = 8.3 ms (60 Hz), sine (50 Hz), sine t = 8.