GENERAL PURPOSE TRANSFORMERS
Control Transformers
Recognized component – Underwriter’s Laboratories, Inc.
High dielectric strength capability for industrial applications
High ET – product allows long pulse width
Electrical Specifications @ 25°C — Operating Temperature 0°C to 70°C
Part Number
PE-61001 PE-61003 PE-61006 PE-61007 PE-61008 PE-61014 PE-61015 PE-61017 PE-61018 PE-61019 PE-61023
Turns Ratio (±10%)
1:1
2:1 1:1:1 1:1:1 1:1:1
1:1 1:1 2:1 2:1 1:1:1 2:1:1
Primary Sine Wave OCL (mH MIN)
1.0
0.2 0.2 1.0 5.0 1.0 5.0 1.0 5.0 0.2 1.0
Primary ET-Constant
(V-µs MIN)
360
180 180 360 866 700 1500 700 1500 290 700
PRI/SEC Cww
(pF MAX)
30
24 30 36 42 36 42 36 42 34 40
PRI/SEC Leakage Inductance
15.0
5.0 5.0 12.0 80.0 26.0 130.0 24.0 125.0 4.7 27.0
Primary DCR
(Ω MAX)
2.8
1.4 — 2.8 6.