Full PDF Text Transcription for PE-64487NL (Reference)
Note: Below is a high-fidelity text extraction (approx. 800 characters) for
PE-64487NL. For precise diagrams, and layout, please refer to the original PDF.
THT Current Sense Transformers & Inductors DVE VDE Approved Designed for switching power supply applications Transformer meets IEC950 insulation requirements Frequency ra...
View more extracted text
ications Transformer meets IEC950 insulation requirements Frequency range from 20kHz to 200kHz Electrical Specifications @ 25°C - Operating Temperature -40°C to +125°C Part Number Transformer with 2-1 T Primaries Schem. Figure Part Number Transformer with 1T Primary Schem. Figure Part Number Inductor without Primary Schem. Figure Secondary Secondary Primary Primary Turns Inductance Inductance RS RT Unipolar Bipolar Ns MH Test Voltage (Ω MAX) (Ω MAX) Amp µ Sec. Amp µ Sec. (MIN) (15.75 KHz) Rating (MAX) Rating (MAX) 1C PE-63586NL 1A PE-51686NL 2A 50 5.0 0.5 0.7 50 150 300 PE-64487NL 1C PE-63587NL 1A PE-51687NL 2A 100 2.0 1.0