RAC60-xxSA
RAC60-xxSA is Single Output manufactured by RECOM.
Features
Regulated Converters
- -
- -
- -
AC-DC Power Supply 60 Watt PCB Mount Package Universal Input Voltage Range 3000VAC Isolation Low Output Ripple and Noise Short Circuit Protected
POWERLINE
AC/DC-Converter
RAC60-SA Series
Selection Guide
Part Number RAC60-05SA RAC60-12SA RAC60-15SA RAC60-24SA Input Range (VAC) 90-264 90-264 90-264 90-264 Output Voltage (VDC) 5 12 15 24 Output Current (m A) 10000 5000 4000 2500 Output Efficiency Ripple & Noise (m Vp-p) % 100 150 200 300 76 80 80 80
60 Watt Single Output
Specifications
( typical at 25°C, nominal input voltage and after warm up time unless otherwise specified )
Input Voltage Range Rated Power Input Frequency Range (for AC Input) Input Current (full load) Inrush Current (<2m S) Leakage Current Output Voltage Accuracy (Full load) Line Voltage Regulation (LL to HL at full load) Minimum Load Output Ripple (20MHz limited) Output Trim Operating Frequency Efficiency at Full Load Isolation Voltage (input to output) Temperature Coefficient Isolation Resistance Short Circuit Protection Operating Temperature Range Storage Temperature Range Humidity Case Material Package Weight MTBF (using MIL-HDBK-217F, 25°C) free air convection, with derating Single Load Voltage Regulation (5% to 100% full load) Single
..
90-264VAC or 120-370VDC 60 Watts max. 47-63Hz 2000m A max. (115VAC) / 1000m A max. (230VAC) 20A max. (115VAC) / 40A max. (230VAC) 3.5m A max. ±2% ±1% typ. ±1% typ. 1% see table ±10% 133k Hz typ. see table 3.000VAC min. ±0.02%/°C typ. 100 MOhm max. Continuous, Hiccup, Automatic Restart
Output Power (%) 125 100 75 50 25 0 -25 -10 0 60 70 80 90 100
Derating Graph
(Ambient Temperature)
Natural Convection
12-24
-25°C to +70°C -40°C to +85°C 95% RH max.
Plastic Resin with Fibreglass (UL94V-0) 420g >130 x 10³ hours
40 50
Ambient Temperature Range (°C)
.re-international.
12-February 2006
POWERLINE
AC/DC-Converter
Simplified Schematics
L Filter Rectifier
RAC60-S_D_TA Series
+Vout
-Vout
Single...