Datasheet4U Logo Datasheet4U.com

BP5035A5 - Non-Isolated AC/DC Converter

📥 Download Datasheet

Datasheet Details

Part number BP5035A5
Manufacturer ROHM
File Size 538.56 KB
Description Non-Isolated AC/DC Converter
Datasheet download datasheet BP5035A5 Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Data Sheet 100VAC Input/−5VDC (200mA) Output Non-Isolated AC/DC Converter BP5035A5 Absolute Maximum Ratings Parameter Input voltage Output current ESD endurance Operating temperature range Storage temperature range Symbol Vi Io Vsurge Topr Tstg Limits −170 200 2 −25 to +80 −25 to +80 Unit V mApk kV °C °C Electrical Characteristics Parameter Symbol Min. Typ. Max. Unit Conditions Input voltage range Output voltage Output current Line regulation Load regulation Output ripple voltage Power conversion efficiency Vi Vo Io Vr Vl Vp η −113 −4.7 0 − − − 50 −141 −5.0 − 0.04 0.05 0.07 60 −170 −5.3 200 0.15 0.15 0.