Click to expand full text
Data Sheet
100VAC Input/−12VDC (200mA) Output
Non-Isolated AC/DC Converter
BP5090-12
Absolute Maximum Ratings
Parameter Input voltage Operating temperature range Storage temperature range Maximum surface temperature Output current
Symbol Vi
Topr Tstg Tsmax
Io
Limits −195 −20 to +85 −25 to +105 100
200
Unit V °C °C °C mA
Electrical Characteristics
Parameter
Symbol Min.
Input voltage range
Vi −113
Output voltage
Vo −11.5
Output current
Io −
Line regulation
Vr −
Load regulation
Vl −
Output ripple voltage Vp
−
Conversion efficiency η
74
Typ. −141 −12.5
− 0.04 0.03 0.07 82
Max. −195 −13.2 200 0.20 0.20 0.