TS1000T
Overview
- High temperature range -40 to 175°C
- Low noise low noise 7 μg/√Hz (typ. in band, 2g)
- Excellent Bias Residual model < ±0.6 mg for ± 2 g range
- Long term Bias Repeatability ±2mg for ±2g range after ageing plan Parameter, typical values TS1002T TS1005T Full-scale acceleration ±2 ±5 Angular accuracy [1]
- 25 Residual Bias modeling error [2]
- 5 Long-term Bias repeatability 2 5 Residual Scale factor modeling error [2] 300 300 Misalignment 10 10 Resolution (1Hz) 7 17 Non Linearity (IEEE norm)
- 3 Operational temperature -40 to +150 -40 to +150 Intermittent temperature -55 to +175 -55 to +175 Shock Survivability 6’000 6’000 Endurance shock (500 times) 1500 1500 Operating power consumption 10 10 Size 9x9 9x9 [1] see definition in paragraph “Using TS1000T for Tilt Application” [2] Using 3rd order polynomial compensation Featured Applications (non-exhaustive) Drilling
- Directional Drilling
- Down-Hole Measurement
- Borehole Survey While Drilling