ABSOLUTE MAXIMUM RATINGS

(unless otherwise specified : Tl=25℃) Item Symbol Conditions Storage temperature Tstg Operating junction temperature Tj Maximum surge reverse power(ZD) PRSM(ZD) 10/1000μs, Non-repetitive Maximum surge reverse current(ZD) IRSM(ZD) 10/1000μs, Non-repetitive Continuous (direct) reverse voltage(ZD) VRM(DC)(ZD) Repetitive peak reverse voltage(Di) VRRM(Di) ※︓See the original Specifications Ratings Unit -40 to 150 ℃ 150 ℃ 200 W 1 A 120 V 600 V Shindengen Electric Manufacturing Co., Ltd. 1/6 ST02D-140_Rev.01(2020.01)

ELECTRICAL CHARACTERISTICS

(unless otherwise specified : Tl=25℃) Item Symbol Conditions Breakdown voltage(ZD) Clamping Voltage(ZD) Reverse current(ZD) Reverse current(Di) Reverse recovery time(Di) Thermal resistance VBR(ZD) IR=1mA VCL(ZD) IPP=1.0A IR(ZD) VR=120V IR(Di) VR=600V trr(Di) IF/IR=0.1A/0.3A Rth(j-l) Junction to lead ※︓See the original Specifications Ratings MIN TYP MAX 130 145 160 200 5 5 500 17 Unit V V μA μA ns ℃/W Shindengen Electric Manufacturing Co., Ltd.