Datasheet4U.com

BCG08-A1AM0318 Datasheet PDF

SICK BCG08-A1AM0318

the BCG08 with PROFINET: 230 mm (wire draw length per revolution - see Mechanical data): 262,144 (number of steps per revolution) = 0.001 mm (resolution of wire draw + encoder combination).
Part No. BCG08-A1AM0318
Datasheet BCG08-A1AM0318 Download
Manufacturer
SICK
Description EcoLine
Buy Stock & Price
BCG08-A1AM0318 datasheet page 1 preview
Online data sheet BCG08-A1AM0318 EcoLine WIRE DRAW ENCODERS BCG08-A1AM0318 | EcoLine WIRE DRAW ENCODERS A B C D E F H I J K L M N O P Q R S T Ordering information Type BCG08-A1AM0318 Other models and accessories Illustration may differ Part no. 1061025 Detailed technical data Performance Measurement range Reproducibility Linearity Hysteresis Resolution (wire draw + encoder) 0 m ... 3 m ≤ 0.2 mm 1) ≤ ± 2 mm 1) ≤ 0.4 mm 1) 0.06 mm 2) 3) 1) Value applies to wire draw mechanism. 2) The values shown have been rounded. 3) Example calculation based on Interfaces Encoder Absolute encoders Electrical interface SSI Connection type Male connector M23, 12-pin, radial Clock frequency 1 MHz 2 MHz Set (electronic adjustment) Via SET cable Type of code for the absolute value Gray Electrical data Initialization time 1) Supply voltage Power consumption MTTFd: mean time to dangerous failure 4.5 V ... 32 V 0.7 W 250 years 2) 3) 1) Valid positional data can be read once this time has elapsed. 2) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive.
BCG08-A1AM0318 page 2 preview BCG08-A1AM0318 page 3 preview