SICK LBV300
LEVEL SENSORS
FEATURES
Medium Measurement Probe length Process pressure Process temperature Fill material density Particle size Tensile strength Performance Accuracy of sensor element Reproducibility Response time Electronics Power consumption Initialization time VDE protection class 1 Connection type Output signal Supply voltage Hysteresis Output current Inductive load Capacitive load Contact load Enclosure rating Mechanics Process connection 2 FLUID SENSORS | SICK Bulk solids Switch 1,300 mm –1 bar ... 6 bar –40 °C ... +150 °C ≥ 0.008 < 10 mm ≤ 3,000 N ± 10 mm ≤ 5 mm 500 ms when covered / 1,000 ms when uncovered 5 mA ... 30 mA < 2 s ✔ M20 x 1.5 Double re