Datasheet4U.com

BTA06-800B Datasheet PDF

STMicroelectronics BTA06-800B

the BTA06 and BTB06 triac series is suitable for general purpose AC switching. They can be used as an ON/OFF function in applications such as static relays, heating regulation, induction motor starting circuits... By using an internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500VRMS) complying with UL standards (File ref.: E81734).
Part No. BTA06-800B
Datasheet BTA06-800B Download
Manufacturer
STMicroelectronics
Description 6A TRIAC
Buy Stock & Price
BTA06-800B datasheet page 1 preview

FEATURES

A2 Symbol Value Unit IT(RMS) VDRM/VRRM IGT (Q1) 6 A 600 and 800 V 5 to 50 mA G A1 A2

DESCRIPTION

Available either in through-hole or surface-mount packages, or for phase control operation in light dimmers, motor speed controllers,... A1 A2 G TO-220AB Insulated (BTA06) A1 A2 G TO-220AB (BTB06) The snubberless and logic level versions (BTA/ BTB...W) are specially recommended for use on inductive loads, thanks to their high commutation performances. Table 2: Order Codes Part Number BTA06-xxxxxRG BTB06-xxxxxRG Table 3:

ABSOLUTE MAXIMUM RATINGS

Symbol IT(RMS) ITSM Parameter RMS on-state current (full sine wave) TO-220AB TO-220AB Ins. Non repetitive surge peak on-state F = 50 Hz current (full cycle, Tj initial = 25°C) F = 60 Hz Tc = 110°C Tc = 105°C t = 20 ms t = 16.7 ms I²t dI/dt IGM PG(AV) Tstg Tj I²t Value for fusing Critical rate of rise of on-state current IG = 2 x IGT , tr ≤ 100 ns Peak gate current Average gate power dissipation tp = 10 ms F = 120 Hz tp = 20 µs Storage juncti...