Datasheet4U.com

BTA12-600B Datasheet PDF

STMicroelectronics BTA12-600B

the BTA/BTB12 and T12 triac series is suitable for general purpose AC switching. They can be used as an ON/OFF function in applications such as static relays, heating regulation, induction motor starting circuits... The snubberless versions (BTA/BTB...W and T12 series) are specially recommended for use on inductive loads, thanks to their high commutation performances.
Part No. BTA12-600B
Datasheet BTA12-600B Download
Manufacturer
STMicroelectronics
Description 12A TRIACS
Buy Stock & Price
BTA12-600B datasheet page 1 preview

FEATURES

: Symbol IT(RMS) VDRM/VRRM IGT (Q ) 1 Value 12 600 and 800 5 to 50 Unit A V mA A1 G A2 A1 A2

DESCRIPTION

Available either in through-hole or surface-mount packages, or for phase control operation in light dimmers, motor speed controllers,... Logic level versions are designed to interface directly with low power drivers such as microcontrollers. By using an internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500V RMS) complying with UL standards (File ref.: E81734) A2 G D2PAK (T12-G) A2 A1 A2 G A1 A2 G TO-220AB Insulated (BTA12) TO-220AB (BTB12)

ABSOLUTE MAXIMUM RATINGS

Symbol IT(RMS) Parameter RMS on-state current (full sine wave) D²PAK/TO-220AB TO-220AB Ins. ITSM Non repetitive surge peak on-state current (full cycle, Tj initial = 25°C) I²t Value for fusing Critical rate of rise of on-state current IG = 2 x IGT , tr ≤ 100 ns F = 50 Hz F = 60 Hz Tc = 105°C 12 Tc = 90°C t = 20 ms t = 16.7 ms 120 126 78 Tj = 125°C Tj = 25°C Tj = 125°C Tj = 125°C 50 VDRM...